Services Offered

  • Air & Water Balance Procedures

    TAB technicians measure, adjust, and report air or water volume, pressures, and/or temperatures. Volumes are adjusted to meet engineered design requirements. Items not within the project design tolerances are noted.
  • Kitchen Hoods & Kitchen Ventilation Systems

    Supply, make up air, and exhaust ventilation rates are tested, adjusted and reported. Kitchen and dish machine hoods are observed for capture and containment.
  • Duct Leakage Testing

    Duct integrity is a consideration of energy efficiency. When specified this additional test procedure may be added.
  • Critical Environment Type Testing

    Examples of critical environment testing are a laboratory or medical procedural rooms. Measure and adjust air flow rates, air changes per hour, room pressurization, and directional air flow.The specific test procedures vary pending lab type and usage. Fume hoods testing and adjustment is frequently involved.
  • HVAC System Commissioning & Verification

    Typically performed on problematic HVAC systems or for energy conservation measures.
  • Sound & Vibration Testing

    When listed these additional tests may be added to the typical test and balance procedures.
  • Life Safety System Component Testing

    Stairwell pressurization and fire/ fire smoke damper testing, are examples of fire life safety system components. This may be performed as a separate additional service.

 

Markets Served

  • Education

    K-12, colleges, universities, and office buildings.
  • Healthcare

    Hospitals, clinics, and pharmaceutical environments
  • Commercial Construction

    Restaurant, retail businesses, office buildings, warehouses, and manufacturing
  • Government

    Aviation, military, instructional, office and transportation buildings
  • Industrial

    Manufacturing, storage, distribution and data centers

 

TAB Instrumentation

Modern HVAC systems are complex. Proper HVAC TAB testing requires the combination of a TAB knowledge base and selected calibrated instruments.

  • Air Meters & Flow Hoods

    TSI/Alnor meter, Flow Hood and Rotating Vane, Dwyer pitot tubes, Evergreen Telemetry meter, Probes, and Flow Hood, Shortridge AirData meter, Flow Hood and Velgrid, Testo instruments, and probes.
  • Hydronic Meters

    Evergreen Telemetry,TSI/Alnor, Dwyer, and Shortridge HydroData multi-meter.
  • Electrical Meters

    Fluke, Amprobe, Fieldpiece, Klein
  • Tachometers

    Contact, non contact, and laser type, Extech, Shimpo, Testo,
  • Duct Leakage Test Kits

    TSI/Alnor, Kanomax, Retrotec,Oriflow
  • Blower Door Kit

    The Energy Conservatory

ASHRAE